Three Phase TOSHIBA G8000MM Series 1
TOSHIBA G8000MM Series UPS (100 to 750kVA)
Three Phase TOSHIBA G8000MM Series 2
TOSHIBA G8000MM Series UPS Open
« »
TOSHIBA G8000MM Series UPS

Toshiba introduces the G8000MM UPS to the Multi Module UPS Market. The G8000MM combines Toshiba reliability and performance with ultimate flexibility to meet the needs of growing businesses.

Features & Benefits

• Technologically Advanced Control of Fast-Switching IGBTs Delivers 94% Efficiency

• Combination Diode Bridge & Broad Range Harmonic Input Filter

• Delivers Low Input Total Harmonic Distortion (THD)

• Low THD Reduces Heat Loss in Associated Feed Equipment & Increases Component Life

• Self-Contained Modular Design Allows Low Cost Future Expansion

• Combine Up to Eight Modules for Increased Capacity or Redundancy

• Highly Efficient Hybrid Static-Transfer Switch Built Into Each Module

• Parallel Output Tie Cabinet Requires Minimal Intelligence Circuitry

• Reducing Purchase Cost

• Superior Output Voltage Regulation Provides Non-Distorted Output

• Power with Minimal Use of Batteries when Subjected to Severe Step Loads

• Generator-Friendly Interface Allows 1.1 KW Generator Capacity to 1.0 KVA UPS Load

• Advanced Battery-Control Ingenuity Produces Low DC Ripple -- Extending Battery & Capacitor Life

• Fail-Safe Design Incorporates Robust, Conservatively Engineered Devices to Reduce Failures & Ensure Reliability

TOSHIBA G8000MM Series UPS
MODEL NUMBER T8MS3K10 KK6XSN T8MS3K15 KK6XSN T8MS3K22 KK6XSN T8MS3K30 KK6XSN T8MS3K37 KK6XSN T8MS3K50 KK6XSN T8MS3K62 KK6XSN T8MS3K75 KK6XSN
CAPACITY
kVA / kW 100/80 150/120 225/180 300/270 375/338 500/450 625/562 750/675
TOPOLOGY True On-Line, Double Conversion
INPUT
Voltage AC Input: 480 V Three-Phase Three-Wire + Ground
Bypass Input: 480 V Three-Phase Four-Wire + Ground
Voltage Range 480 V +15% to -15% (408 to 552 V Without Utilizing Battery)
Power Factor Greater than 0.98
Current THD <6% at 100% Load; 9% Maximum at 50% Load
Frequency 60 Hz (± 5%)
Walk-In 5 to 30 Seconds (Adjustable)
OUTPUT
Voltage 480/277 V, Three-Phase Four-Wire + Ground
Frequency 60 Hz ±0.05% in Free-Running Mode
Voltage Regualtion ±1%
Power Factor 0.8 Lagging 0.9 Lagging
Voltage THD 2% Maximum THD at 100% Linear Load
5% Maximum THD at 100% Non-Linear load
Transient Response ±2% Maximum THD at 100% Step Load
±1% Maximum at Loss/Return of AC Power
±5% Maximum at Load Transfer to/from Static Bypass
Transient Recovery < 16.7 ms
Voltage Unbalance 1% Maximum at 100% Unbalanced Load
Phase Displacement 1° Maximum at 100% Load
Overload (Inverter) 125% for 10 Minutes; 150% for 1 Minute
Overload (System) 1000% for One Cycle (Available with Bypass) 500% for One Cycle (Available with Bypass)
BATTERY
Type Lead Acid (VRLA or Flooded)
Nominal Voltage 480 VDC
Minimum Voltage 400 VDC
Charge Current (ADC) 13 19.5 29.3 39 48.7 65 92.5 92.5
Number of Cells 240
ENVIRONMENT
Cooling Forced Air
Temperature Range 32° to 104°F (0° to 40°C) During Operating and Storage
Relative Humidity 5% to 95% Non-Condensing
Heat Rejection (BTU/h) 18,353 26,465 44,105 60,894 76,117 96,271 120,339 144,407
Efficiency (100% load) 93.7% 93.5% 93.3% 93.8% 93.8% 94.1% 94.1% 94.1%
Altitude 0 to 9000 ft.
Audible Noise @ 1m 68 DBA 72 DBA 76 DBA 78 DBA 80 DBA
Dimensions
Width 43.3 in. 47.2 in. 55.1 in. 76.8 in. 114.2 in. 129.9 in.
Depth 29.8 in. 37.7 in. 49.5 in.
Height 79.7 in.
Weight 2061 lbs. 2579 lbs. 3263 lbs. 4564 lbs. 4916 lbs. 6923 lbs. 9193 lbs.
FEATURES
Dual-Input Feed Output Isolation Transformer, RS232 and Dry Contact Interface, Single or Parallel Operation
STANDARDS UL1778, CUL, NEMA PE1, ISO9001, ANSI C62.41 (IEEE 587)
WARRANTY Three-Year Warranty on UPS Electronics Standard, Up to Five Years Available; Three-Year Warranty on Batteries with Startup Purchase; See Toshiba Warranty Policy for Full Details
SERVICE 24-Hour, 365-Day Technical Support 1-877-867-8773